8400 HighLine | Parameter setting & configuration
Commissioning
Quick commissioning
38 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
3.3 Quick commissioning
For controlling the controller, please select
keypad control if you want to use the X400 keypad as the control source. You can find
the associated description in the chapter entitled "Keypad control
". ( 38)
terminal control if you want to use a setpoint potentiometer as the control source. You
can find the associated description in the chapter entitled "Terminal control
". ( 41)
Tip!
Please read up on keypad handling first:
Handling the keypad
( 31)
3.3.1 Keypad control
Commissioning steps
1. Wire the power connections
– Refer to the mounting instructions supplied with the drive controller to find help on
how to correctly design the power connections to match the requirements of your
device.
2. Wire the control connections
3. Load the Lenze setting into the controller
Digital inputs at terminal X5 Assignment Info
RFR • Controller enabling:
RFR = High
•Error resetting:
RFR = HIGHÌLOW (edge-controlled)
After the keypad has been plugged in
or the drive controller has been
switched on with the keypad
plugged in, a connection is first
established between the keypad and
the drive controller.
• The process is completed if code
C00051 appears in the display.
• Then press the left function key.
24E
DI4
DI3
DI2 DI1
RFR
GI 24I
DI7
DI5
DI6
MCTRL: Act. speed val.
C00051
0 rpm