C00711
Parameter | Name:
C00711 | LA_TabPos: Analog connection list
Data type: UNSIGNED_16
Index: 23864
d
= 5D38
h
Connection parameters for "Table positioning" application: Binary inputs
• Selection of the binary output signals for connection with the binary input signals
• The selection list contains all binary output signals which can be assigned to the binary inputs mapped by the
subcodes.
Selection list
See selection list - digital signals
Subcodes Lenze setting Info
C00711/1 0: Not connected LA_TabPos
: bCInh
(control input for setting controller inhibit)
C00711/2 0: Not connected LA_TabPos
: bFailReset
(control input for error acknowledgement)
C00711/3 0: Not connected LA_TabPos
: bSetQuickstop
(control input for quick stop request)
C00711/4 0: Not connected LA_TabPos
: bSetSpeedCcw
(control input for negation of speed direction)
C00711/5 0: Not connected LA_TabPos
: bJogSpeed1
(control input for fixed speed selection valency 1)
C00711/6 0: Not connected LA_TabPos
: bJogSpeed2
(control input for fixed speed selection valency 2)
C00711/7 0: Not connected LA_TabPos
: bMPotEnable
(control input for activation of motor potentiometer)
C00711/8 0: Not connected LA_TabPos
: bMPotUp
(control input for motor potentiometer ramp-up)
C00711/9 0: Not connected LA_TabPos
: bMPotDown
(control input for motor potentiometer ramp-down)
C00711/10 0: Not connected LA_TabPos
: bMBrakeRelease
(control input for manual holding brake release request)
C00711/11 0: Not connected LA_TabPos
: bPosCtrlOn
(control input for activation of position controller)
C00711/12 0: Not connected LA_TabPos
: bLimitSwitchPos
(input for positive hardware limit switch signal)
C00711/13 0: Not connected LA_TabPos
: bLimitSwitchNeg
(input for negative hardware limit switch signal)
C00711/14 0: Not connected LA_TabPos
: bReleaseLimitSwitch
(control input for hardware limit switch retracting
request)
C00711/15 0: Not connected LA_TabPos
: bManJogPos
(control input for manual jog in positive direction
request)
C00711/16 0: Not connected LA_TabPos
: bManJogNeg
(control input for manual jog in negative direction
request)
C00711/17 0: Not connected LA_TabPos
: bManEnable2ndSpeed
(control input for activation of the second manual speed
for manual jog)
C00711/18 0: Not connected LA_TabPos
: bEnableSpeedOverride
(control input for activation of speed override)
C00711/19 0: Not connected LA_TabPos
: bEnableAccOverride
(control input for activation of acceleration override)
C00711/20 0: Not connected LA_TabPos
: bHomeStartStop
(control input for start/stop homing)
efesotomasyon.com - Lenze