8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C01100
C01100
C01101
C01120
Parameter | Name:
C01100 | Function L_Counter 1-3
Data type: UNSIGNED_8
Index: 23475
d
= 5BB3
h
Selection of reset function
Selection list
0Normal counting
1Auto reset
2Manual reset
Subcodes Lenze setting Info
C01100/1 0: Normal counting L_Counter_1
: Function
C01100/2 0: Normal counting L_Counter_2
: Function
C01100/3 0: Normal counting L_Counter_3
: Function
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01101 | Comparison L_Counter 1-3
Data type: UNSIGNED_8
Index: 23474
d
= 5BB2
h
Selection of comparison operation
Selection list
0 Greater than or equal to
1 Less than or equal to
2equal to
Subcodes Lenze setting Info
C01101/1 0: Greater than or equal to L_Counter_1
: Comparison
C01101/2 0: Greater than or equal to L_Counter_2
: Comparison
C01101/3 0: Greater than or equal to L_Counter_3
: Comparison
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01120 | Sync signal source
Data type: UNSIGNED_8
Index: 23455
d
= 5B9F
h
As of version 02.00.00
Selection of the signal source for device synchronisation
• Basically, only one source can synchronise the drive.
Selection list (Lenze setting printed in bold) Info
0Off Synchronisation off
1 CAN on board Synchronisation via "CAN on board" system bus
Sync telegram
4 MCI Synchronisation via MCI (communication module)
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1