Firmware 05.00 - DMS 4.2 EN - 02/2010 L 597
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00039
C00039
C00050
C00051
Parameter | Name:
C00039 | Fixed setpoint x (L_NSet_1 n-Fix)
Data type: INTEGER_16
Index: 24536
d
= 5FD8
h
FB L_NSet_1: Fixed speed setpoints (JOG values) for the setpoint generator
Setting range (min. value | unit | max. value)
-199.99 % 199.99
Subcodes Lenze setting Info
C00039/1 40.00 % Fixed setpoint 1
C00039/2 60.00 % Fixed setpoint 2
C00039/3 80.00 % Fixed setpoint 3
C00039/4 0.00 % Fixed setpoint 4
C00039/5 0.00 % Fixed setpoint 5
C00039/6 0.00 % Fixed setpoint 6
C00039/7 0.00 % Fixed setpoint 7
C00039/8 0.00 % Fixed setpoint 8
C00039/9 0.00 % Fixed setpoint 9
C00039/10 0.00 % Fixed setpoint 10
C00039/11 0.00 % Fixed setpoint 11
C00039/12 0.00 % Fixed setpoint 12
C00039/13 0.00 % Fixed setpoint 13
C00039/14 0.00 % Fixed setpoint 14
C00039/15 0.00 % Fixed setpoint 15
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00050 | MCTRL: Speed setpoint
Data type: INTEGER_32
Index: 24525
d
= 5FCD
h
Display of the speed setpoint at the speed setpoint input of the motor control
Display range (min. value | unit | max. value)
-60000 rpm 60000
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00051 | MCTRL: Actual speed value
Data type: INTEGER_32
Index: 24524
d
= 5FCC
h
Display of the actual speed value of the motor shaft
Note:
The displayed value only corresponds to the real actual speed value of the motor shaft if an encoder is connected to
the motor and the evaluation of the feedback signal has been set correctly ("Closed loop" operation).
In case of operation without speed feedback, the signal is calculated from the motor control and thus may not
correspond to the real actual speed.
Display range (min. value | unit | max. value)
-60000 rpm 60000
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 1