8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00586
672 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
C00586
C00588
C00590
C00592
Parameter | Name:
C00586 | Resp. to encoder wire breakage
Data type: UNSIGNED_8
Index: 23989
d
= 5DB5
h
Response for a failure of the encoder feedback system or the encoder feedback system track due to an open circuit
Selection list (Lenze setting printed in bold)
0 No Reaction
1Fault
5 Warning
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00588 | Resp. to max speed at switch. freq
Data type: UNSIGNED_8
Index: 23987
d
= 5DB3
h
Response for reaching the maximum speed for the set inverter switching frequency (C00018)
Selection list (Lenze setting printed in bold)
0No Reaction
1Fault
5 Warning
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00590 | Resp. to switch. frequency red.
Data type: UNSIGNED_8
Index: 23985
d
= 5DB1
h
Response to reduction of the inverter switching frequency (C00018)
Selection list (Lenze setting printed in bold)
0No Reaction
1Fault
5 Warning
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00592 | Resp. to CAN bus connection
Data type: UNSIGNED_8
Index: 23983
d
= 5DAF
h
Configuration of monitoring of the CAN interface (group 1)
System bus "CAN on board"
Selection list
0 No Reaction
1Fault
2Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information
Subcodes Lenze setting Info
C00592/1 0: No Reaction Response to incorrect telegram for CAN communication
C00592/2 0: No Reaction Response to "BusOff" (bus system switched off)
C00592/3 0: No Reaction Response to warnings of the CAN controller
C00592/4 0: No Reaction Response to communication stop of a CAN bus node
C00592/5 0: No Reaction Response to an event in the case of monitoring via
heartbeat protocol
; Read access ; Write access CINH PLC STOP No transfer ; COM MOT Scaling factor: 1