Lenze E84AVHC Series - C00059 | Appl.: Reference frequency C11; C00061 | Heatsink temperature; C00064 | Device utilisation (Ixt); C00065 | 24 V supply voltage

Lenze E84AVHC Series
1118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware 05.00 - DMS 4.2 EN - 02/2010 L 599
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00059
C00059
C00061
C00064
C00065
C00066
Parameter | Name:
C00059 | Appl.: Reference frequency C11
Data type: UNSIGNED_32
Index: 24516
d
= 5FC4
h
Display of the field frequency which corresponds to the reference speed set in C00011.
Display range (min. value | unit | max. value)
0.00 Hz 1300.00
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00061 | Heatsink temperature
Data type: INTEGER_16
Index: 24514
d
= 5FC2
h
Display of the current heatsink temperature
Display range (min. value | unit | max. value)
-50 °C 150
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00064 | Device utilisation (Ixt)
Data type: INTEGER_16
Index: 24511
d
= 5FBF
h
Display of the device utilisation Ixt in different time resolutions
If the value displayed here exceeds the threshold set in C00123
, the fault message "OC5: Device overload (Ixt)"
is output and the fault response set in C00604
is executed (default setting: "Warning").
Display range (min. value | unit | max. value)
0.00 % 250.00
Subcodes Info
C00064/1 Device utilisation (Ixt)
Maximum value of the pulse utilisation (C00064/2)
and permanent utilisation (C00064/3).
C00064/2 Device utilisation (Ixt) 15s
Pulse utilisation over the last 15 seconds (only for
loads >160 %).
C00064/3 Device utilisation (Ixt) 3 min
Permanent utilisation over the last 3 minutes.
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00065 | 24 V supply voltage
Data type: INTEGER_16
Index: 24510
d
= 5FBE
h
Display of the 24V supply voltage for the supply of the control electronics
Note:
The 24 V supply for the control electronics is either provided by an external supply or by the controller itself if it is
connected to the mains voltage.
Display range (min. value | unit | max. value)
0.0 V 3276.7
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 10
Parameter | Name:
C00066 | Thermal motor load (I²xt)
Data type: INTEGER_16
Index: 24509
d
= 5FBD
h
Display of the thermal motor load being detected sensorless via a motor model
If the value displayed here exceeds the threshold set in C00120
, the fault message "OC6: Thermal motor overload
(I2xt)" is output and the fault response set in C00606
is executed (default setting: "Warning").
Display range (min. value | unit | max. value)
0.00 % 199.99
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 100