EasyManua.ls Logo

Lenze E84AVHC Series - 14.1.103 L_OffsetGainP_1

Lenze E84AVHC Series
1118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware 05.00 - DMS 4.2 EN - 02/2010 L 1015
8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_OffsetGainP_1
14.1.103 L_OffsetGainP_1
This FB can add an offset to an analog input signal and amplify it afterwards. Preferably to
be interconnected directly after the analog input terminals.
The internal calculations (addition and subtraction) are carried out with 32 bits without
overflow/underflow.
Offset and gain are selected via parameters.
The value provided at the nOut_a output is internally limited to ±199.99 %.
Inputs
Outputs
Parameter
Function
Identifier
Data type
Information/possible settings
nIn_a
INT
Input signal
Identifier
Data type
Value/meaning
nOut_a
INT
Output signal
Internal limitation to ±199.99 %
Parameter Possible settings Info
C00670
-100.0000 100.0000 Gain factor
High gain factor for further
processing of smallest input
signals.
Please observe the difference
with regard to the gain factors of
other blocks in percent
(±199.99 % 2).
Lenze setting: 1.0000
C00696
-199.99 % 199.99 Offset
Lenze setting: 0.00 %
/B2IIVHW*DLQ3B
Q2XWBD


Q,QBD
2IIVHW *DLQ
& &
nOut_a nIn_a Offset+()Gain factor=