8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C01300
784 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
C01300
C01301
C01302
Parameter | Name:
C01300 | Profile data: Positioning mode
Data type: UNSIGNED_8
Index: 23275
d
= 5AEB
h
Selection of the positioning mode for profiles 1 ... 15
Profile entry
Selection list Info
1 Absolute (shortest path) Absolute positioning
• The profile position corresponds to the target
position.
2 Continuous Continuous positioning without approaching a target
position
3 Relative Relative positioning
• The profile position determines the distance to be
traversed.
Subcodes Lenze setting Info
C01300/1 1: absolute (beeline) Profiles 1 ... 15: Positioning mode
C01300/...
C01300/15
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01301 | Profile data: Position
Data type: INTEGER_32
Index: 23274
d
= 5AEA
h
Selection of the positions for profiles 1 ... 15
Profile entry
Setting range (min. value | unit | max. value)
-214748.3647 unit 214748.3647
Subcodes Lenze setting Info
C01301/1 360.0000 unit Profiles 1 ... 15: Position
C01301/...
C01301/15
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C01302 | Profile data: Speed
Data type: INTEGER_32
Index: 23273
d
= 5AE9
h
Selection of the maximum speeds for profiles 1 ... 15
Profile entry
Setting range (min. value | unit | max. value)
-214748.3647 unit/s 214748.3647
Subcodes Lenze setting Info
C01302/1 360.0000 unit/s Profiles 1 ... 15: Speed
C01302/...
C01302/15
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000