Firmware 05.00 - DMS 4.2 EN - 02/2010 L 679
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00621
C00621
C00620/50 0: Not connected LS_ParReadWrite_1
: wParSubindex
C00620/51 0: Not connected LS_ParReadWrite_1
: wInHWord
C00620/52 0: Not connected LS_ParReadWrite_1
: wInLWord
C00620/53 0: Not connected LS_ParReadWrite_2
: wParIndex
C00620/54 0: Not connected LS_ParReadWrite_2
: wParSubindex
C00620/55 0: Not connected LS_ParReadWrite_2
: wInHWord
C00620/56 0: Not connected LS_ParReadWrite_2
: wInLWord
C00620/57 0: Not connected LS_ParReadWrite_3
: wParIndex
C00620/58 0: Not connected LS_ParReadWrite_3
: wParSubindex
C00620/59 0: Not connected LS_ParReadWrite_3
: wInHWord
C00620/60 0: Not connected LS_ParReadWrite_3
: wInLWord
C00620/61 0: Not connected LS_ParReadWrite_4
: wParIndex
C00620/62 0: Not connected LS_ParReadWrite_4
: wParSubindex
C00620/63 0: Not connected LS_ParReadWrite_4
: wInHWord
C00620/64 0: Not connected LS_ParReadWrite_4
: wInLWord
C00620/65 0: Not connected LS_ParReadWrite_5
: wParIndex
C00620/66 0: Not connected LS_ParReadWrite_5
: wParSubindex
C00620/67 0: Not connected LS_ParReadWrite_5
: wInHWord
C00620/68 0: Not connected LS_ParReadWrite_5
: wInLWord
C00620/69 0: Not connected LS_ParReadWrite_6
: wParIndex
C00620/70 0: Not connected LS_ParReadWrite_6
: wParSubindex
C00620/71 0: Not connected LS_ParReadWrite_6
: wInHWord
C00620/72 0: Not connected LS_ParReadWrite_6
: wInLWord
C00620/73 0: Not connected Reserved
C00620/74 0: Not connected Reserved
C00620/75 0: Not connected Reserved
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00620 | System connection list: 16-bit
Data type: UNSIGNED_16
Index: 23955
d
= 5D93
h
Parameter | Name:
C00621 | System connection list: Bool
Data type: UNSIGNED_16
Index: 23954
d
= 5D92
h
Connection parameters: Binary inputs
Selection of the binary output signals for connection with the binary input signals.
The selection list contains all binary output signals which can be assigned to the binary inputs mapped by the
subcodes.
Selection list
See selection list - digital signals
Subcodes Lenze setting Info
C00621/1 1001: LA_nCtrl_bDriveFail LS_DigitalOutput
:bRelay
C00621/2 1000: LA_nCtrl_bDriveReady LS_DigitalOutput
:bOut1
C00621/3 0: Not connected LS_DigitalInput
: bCountIn1_Reset
C00621/4 0: Not connected LS_DigitalInput
: bCountIn1_LoadStartValue
C00621/5 0: Not connected LP_CanOut1
: bState_B0
C00621/6 0: Not connected LP_CanOut1
: bState_B1
C00621/7 0: Not connected LP_CanOut1
: bState_B2
C00621/8 0: Not connected LP_CanOut1
: bState_B3