EasyManua.ls Logo

Lenze E84AVHC Series - C02607 | Holding brake: Status; C02610 | MCK: Accel.;decel. times

Lenze E84AVHC Series
1118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C02607
792 L Firmware 05.00 - DMS 4.2 EN - 02/2010
C02607
C02610
Parameter | Name:
C02607 | Holding brake: Status
Data type: UNSIGNED_16
Index: 21968
d
= 55D0
h
Switching status of the holding brake control
Holding brake control
Display area (min. hex value | max. hex value)
0x0000 0xFFFF
Value is bit-coded: Info
Bit 0 Brake closed Holding brake is completely applied
Bit 1 Brake released Holding brake is completely released
Bit 2 Feedforward control active Feedforward control for holding of the load via the motor
is active before the holding brake releases.
Bit 3 Closing active The brake application time (C02589/1) expires
Bit 4 Forced release active In case of automatic operation of the holding brake
control, the brake is directly released via the MCK input
bBrkRelease =TRUE
Bit 5 Release active The brake application time (C02589/2) expires
Bit 6 Setpoint synchronisation active A speed setpoint at the MCK is approached along a
defined ramp after brake release
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
; Read access Write access CINH PLC STOP ; No transfer COM MOT
Parameter | Name:
C02610 | MCK: Accel./decel. times
Data type: UNSIGNED_32
Index: 21965
d
= 55CD
h
Ramp times for speed setpoint synchronisation
Setting range (min. value | unit | max. value)
0.000 s 999.999
Subcodes Lenze setting Info
C02610/1 2.000 s MCK: Holding brake ramp time synchr.
Ramp time for approaching the speed setpoint at the
MCK after holding brake release.
Holding brake control
C02610/2 2.000 s MCK: Setpoint - ramp time synchronisation
Time for synchronisation ramps between setpoint
jumps occurring through the exceedance of
minimum and maximum speed setpoint limit ranges.
C02610/3 2.000 s MCK: SM stopping ramp
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000