8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C02607
792 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
C02607
C02610
Parameter | Name:
C02607 | Holding brake: Status
Data type: UNSIGNED_16
Index: 21968
d
= 55D0
h
Switching status of the holding brake control
Holding brake control
Display area (min. hex value | max. hex value)
0x0000 0xFFFF
Value is bit-coded: Info
Bit 0 Brake closed Holding brake is completely applied
Bit 1 Brake released Holding brake is completely released
Bit 2 Feedforward control active Feedforward control for holding of the load via the motor
is active before the holding brake releases.
Bit 3 Closing active The brake application time (C02589/1) expires
Bit 4 Forced release active In case of automatic operation of the holding brake
control, the brake is directly released via the MCK input
bBrkRelease =TRUE
Bit 5 Release active The brake application time (C02589/2) expires
Bit 6 Setpoint synchronisation active A speed setpoint at the MCK is approached along a
defined ramp after brake release
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
; Read access Write access CINH PLC STOP ; No transfer COM MOT
Parameter | Name:
C02610 | MCK: Accel./decel. times
Data type: UNSIGNED_32
Index: 21965
d
= 55CD
h
Ramp times for speed setpoint synchronisation
Setting range (min. value | unit | max. value)
0.000 s 999.999
Subcodes Lenze setting Info
C02610/1 2.000 s MCK: Holding brake ramp time synchr.
• Ramp time for approaching the speed setpoint at the
MCK after holding brake release.
Holding brake control
C02610/2 2.000 s MCK: Setpoint - ramp time synchronisation
• Time for synchronisation ramps between setpoint
jumps occurring through the exceedance of
minimum and maximum speed setpoint limit ranges.
C02610/3 2.000 s MCK: SM stopping ramp
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000