Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010 L 417
8400 HighLine | Parameter setting & configuration
Basic drive functions (MCK)
Positioning
8.8.2.1 Functional settings
In C01216
, various functional settings regarding behaviour in the case of a changeover to
the "positioning" mode can be made in bit-coded form.
When this is being done, any mode change must be taken into account.
Positioning with controller inhibit/enable is also possible if the corresponding setting
is made.
PosAbort at PosInit
If this function has been activated by means of bit 0 in C01216
and a changeover to
"positioning" mode is made, ramping down at the rate of deceleration set in C01251
for
normal stopping to a standstill is carried out.
PosExecute active at PosInit
If this function has been activated by means of bit 1 in C01216
and a changeover is made
to the "positioning" mode, the specified profile is immediately executed if the "PosExecute"
control bit has also been set.
ProfilStart at PosInit
If this function has been activated by means of bit 4 in C01216
and a changeover is made
to the "positioning" mode, the specified profile is immediately executed.
Related topics:
Stipulation of the profile to be executed
( 424)
Starting/cancelling a traversing task
( 425)
Function Lenze setting
Bit 0 PosAbort at PosInit Off
Bit 1 PosExecute active at PosInit Off
Bit 2 Reserved Off
Bit 3 Reserved Off
Bit 4 ProfilStart at PosInit Off
Bit 5 Reserved Off
Bit 6 Reserved Off
Bit 7 Reserved Off
Note!
In the case of multiple selection, the "PosAbort at PosInit" function, which can be
activated by means of bit 0, has priority over the other functions.