8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00695
692 L Firmware 05.00 - DMS 4.2 EN - 02/2010
C00695
C00696
C00697
C00698
C00699
Parameter | Name:
C00695 | L_Compare 4-5: Window
Data type: INTEGER_16
Index: 23880
d
= 5D48
h
Window for the comparison function selected in C00693
Setting range (min. value | unit | max. value)
0.00 % 100.00
Subcodes Lenze setting Info
C00695/1 0.00 % L_Compare_4
: Window
C00695/2 0.00 % L_Compare_5
: Window
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00696 | L_OffsetGainP_1: offset
Data type: INTEGER_16
Index: 23879
d
= 5D47
h
FB L_OffsetGainP_1: Offset (acts additively to the input signal)
Setting range (min. value | unit | max. value) Lenze setting
-199.99 % 199.99 0.00 %
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00697 | L_OffsetGainP_2: offset
Data type: INTEGER_16
Index: 23878
d
= 5D46
h
FB L_OffsetGainP_2: Offset (acts additively to the input signal)
Setting range (min. value | unit | max. value) Lenze setting
-199.99 % 199.99 0.00 %
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00698 | L_OffsetGainP_3: offset
Data type: INTEGER_16
Index: 23877
d
= 5D45
h
FB L_OffsetGainP_3: Offset (acts additively to the input signal)
Setting range (min. value | unit | max. value) Lenze setting
-199.99 % 199.99 0.00 %
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00699 | L_MulDiv_1: parameter
Data type: INTEGER_16
Index: 23876
d
= 5D44
h
FB L_MulDiv_1: Numerator and denominator
Setting range (min. value | unit | max. value)
-32767 32767
Subcodes Lenze setting Info
C00699/1 0 L_MulDiv_1
: Numerator
C00699/2 10000 L_MulDiv_1
: Denominator
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
efesotomasyon.com - Lenze

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze E84AVHC Series and is the answer not in the manual?

Lenze E84AVHC Series Specifications

General IconGeneral
BrandLenze
ModelE84AVHC Series
CategoryInverter Drive
LanguageEnglish

Related product manuals