Firmware 05.00 - DMS 4.2 EN - 02/2010 L 767
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C01203
C01203
C01204
C01205
C01206
Parameter | Name:
C01203 | Axis data: iG motor/pos. encoder
Data type: UNSIGNED_16
Index: 23372
d
= 5B4C
h
Gearbox factor - position encoder
Entry of the gearbox factor as numerator/denominator ratio, with numerator = motor speed and denominator
= position encoder speed.
Machine parameter
Setting range (min. value | unit | max. value)
1 65535
Subcodes Lenze setting Info
C01203/1 1 iG: Numerator (motor speed)
C01203/2 1 iG: Denominator (encoder speed)
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01204 | Axis data: Feed constant
Data type: INTEGER_32
Index: 23371
d
= 5B4B
h
The feed constant corresponds to the machine movement for one revolution of the gearbox output shaft.
The value is entered in application units referred to one revolution.
Machine parameter
Setting range (min. value | unit | max. value) Lenze setting
0.0001 units/rev. 214748.3647 360.0000 units/rev.
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C01205 | Axis data: Position resolution
Data type: INTEGER_32
Index: 23370
d
= 5B4A
h
Display of the number of increments corresponding to one unit.
1 motor revolution 65536 increments
Machine parameter
Display range (min. value | unit | max. value)
0.0000 incr/unit 214748.3647
; Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C01206 | Axis data: Mounting direction
Data type: UNSIGNED_8
Index: 23369
d
= 5B49
h
Inversion for mirrored motor and encoder mounting
Machine parameter
Selection list
0not inverted
1inverted
Subcodes Lenze setting Info
C01206/1 0: Not inverted Motor mounting direction
Setting for motor mounting turned by 180°.
C01206/2 0: Not inverted Position encoder mounting direction
Setting for position encoder system mounting turned
by 180°.
; Read access ; Write access ; CINH PLC STOP No transfer COM MOT Scaling factor: 1