8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00159
C00159
C00161
Parameter | Name:
C00159 | Cause for quick stop QSP
Data type: UNSIGNED_16
Index: 24416
d
= 5F60
h
Bit-coded display of the cause/source of quick stop
Display area (min. hex value | max. hex value)
0x0000 0xFFFF
Value is bit-coded:
Bit 0 Reserved
Bit 1 CAN control word
Bit 2 MCI control word
Bit 3 Reserved
Bit 4 Application
Bit 5 Controller command
Bit 6 Error response
Bit 7 Internal signal
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Operating system
Bit 11 Reserved
Bit 12 MCK
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
; Read access Write access CINH PLC STOP ; No transfer COM MOT
Parameter | Name:
C00161 | LS_SetError_x: Error number
Data type: UNSIGNED_16
Index: 24414
d
= 5F5E
h
Setting of the error number for user error messages
Setting range (min. value | unit | max. value)
0 65535
Subcodes Lenze setting Info
C00161/1 1 LS_SetError_1
: Error no.1
C00161/2 2 LS_SetError_1
: Error no.2
C00161/3 3 LS_SetError_1: Error no.3
C00161/4 4 LS_SetError_1
: Error no.4
C00161/5 1 LS_SetError_2
: Error no.1
C00161/6 2 LS_SetError_2
: Error no.2
C00161/7 3 LS_SetError_2
: Error no.3
C00161/8 4 LS_SetError_2
: Error no.4
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1