8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00598
C00598
C00599
C00600
C00601
Parameter | Name:
C00598 | Resp. to open circuit AINx
Data type: UNSIGNED_8
Index: 23977
d
= 5DA9
h
Configuration of monitoring of the analog inputs
Analog terminals
Selection list
0 No Reaction
1Fault
2Trouble
3 TroubleQuickStop
5 Warning
Subcodes Lenze setting Info
C00598/1 3: TroubleQuickStop Response to open circuit at AIN1 when being configured
as 4 ... 20 mA-current loop
C00598/2 3: TroubleQuickStop Response to open circuit at AIN2 when being configured
as 4 ... 20 mA-current loop
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00599 | Motor phase failure threshold
Data type: INTEGER_16
Index: 23976
d
= 5DA8
h
Threshold for motor phase failure monitoring
•100% rated inverter current (C00098
)
If a phase current does not exceed the threshold set here over a period, the response to motor phase failure set
in C00597
is effected.
Setting range (min. value | unit | max. value) Lenze setting
1.00 % 100.00 5.00 %
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00600 | Resp. to DC-bus voltage
Data type: UNSIGNED_8
Index: 23975
d
= 5DA7
h
Configuration of monitoring of the motor control (group 3)
Selection list
1Fault
2Trouble
Subcodes Lenze setting Info
C00600/1 2: Trouble Response to undervoltage in the DC bus
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00601 | Delayed resp. fault: DC-bus overvoltage
Data type: UNSIGNED_16
Index: 23974
d
= 5DA6
h
Delay times for error responses
Setting range (min. value | unit | max. value)
0.000 s 65.000
Subcodes Lenze setting Info
C00601/1 2.000 s Delay time for error activation "DC-bus overvoltage"
In case of DC-bus overvoltage, an error is only
transmitted after this delay time has elapsed.
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000