8400 HighLine | Parameter setting & configuration
Basic drive functions (MCK)
MCKInterface
374 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
8.3 MCKInterface
The so-called "MCK interface" described in this chapter consists of the two function blocks
L_MckCtrlInterface
and L_MckStateInterface, which are connected upstream respectively
downstream of the LS_MotionControlKernel
system block:
[8-3] Detail of the interconnection architecture for the "table positioning" technology application
Control and setpoint signals for motor control
Additional process inputs for controlling the Motion Control Kernel, e.g.:
– Selection of the operating mode
– Selection of the profile number
– Override of the positioning mode
– Control inputs for manual jogging, homing, positioning
– Control inputs for speed/acceleration/S-ramp override
Control and setpoint signals for the Motion Control Kernel such as
– Selection of speed setpoint for speed follower
– Selection of positioning setpoint for position follower
– Selection of override values
– Connection for limit switch & pre-stop mark for homing
– Holding brake control
Output of status signals of the Motion Control Kernel
wInMckPosCtrl_1
L_MckCtrlInterface_1
wInMckPosCtrl_2
wOutMckPosCtrl_1
wOutMckPosCtrl_2
bFail
wFailState
bPosSetDataValid
dnPosSetOut_p
Control interface
wInMckPosState_1
L_MckStateInterface_1
wInMckPosState_2
wMotionCtrl1
LS_MotionControlKernel
wMotionCtrl2
wMotionState1
wMotionState2
LS_MotorInterface
Motor
interface
1
2
3
0
Motion Control Kernel
State interface