8400 HighLine | Parameter setting & configuration
Motor control (MCTRL)
V/f characteristic control (VFCplus)
126 L Firmware 05.00 - DMS 4.2 EN - 02/2010
5.4.4 Signal flow
[5-9] Signal flow for V/f characteristic control (VFCplus)
PWM
fPWM:
C00018
8
6
f :
C00910/1 /2
max
f :
C00910/1 /2
max
n :
C00909/1 /2
max
nBoost_a
C00830/26
nMotorSpeedAct_a
C00051
f
Mod
nMotorVoltage
C00052
C00006
nEffCurrentIq
nEffSpeedSetValue_a
C00050
0
1
nSpeedSetValue_a
C00830/22
bSetQSP
Hz
%
Hz
%
nMotorFreqAct_a
C00058
nMotorTorqueAct_a
nOutputSpeedCtrl_a
C00056/1
C00105
Slipcomp
C00021
Hz
Hz
%
%
:C00015
:C00016
V :C00073/1
p
T :C00074/1
N
nStatorCurrentIs
C00054
nMotorTorqueAct_a
C00056/2
nTorqueMotLim_a
C00830/28
C00830/29
nTorqueGenLim_a
I :C00022
I :C00023
max Mot
max Gen
bLimCurrentSetVal
bLimSpeedCtrlOut
0
1
bLimTorqueSetVal
nPWMAngleOffset_a
C00830/32
nVoltageAdd_a
C00830/31
10
:C00015
:C00016
nBoost_a
C00830/26
Modulator
Characteristic
selection
Slip compensation
I controller
max
Coordinate
transformation
Inverter
error
characteristic
V/f linear
V/f-quadr
QSP ramp
f
V
base
min
V
set
Motor slip model
V/f definable
f
V
base
min
C00967/n: Frequency curve base n