Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010 L 659
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00446
C00446
C00447
Parameter | Name:
C00446 | FreqInxx_nOut_a
Data type: INTEGER_16
Index: 24129
d
= 5E41
h
As of version 02.00.00
Display of the frequency input signals supplied into the application.
Using DI1(6) and DI2(7) as frequency inputs
Display range (min. value | unit | max. value)
-199.99 % 199.99
Subcodes Info
C00446/1 FreqIn12_nOut_a
C00446/2 FreqIn67_nOut_a
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00447 | Decoupling: DigOut
Data type: UNSIGNED_16
Index: 24128
d
= 5E40
h
As of version 04.00.00
Configuration defining the events that lead to a decoupling of the digital output terminals.
Configuring exception handling of the output terminals
Setting range (min. hex value | max. hex value) Lenze setting
0x0000 0xFFFF 0x0000 (decimal: 0)
Value is bit-coded: (; =bit set)
Bit 0 SafeTorqueOff
Bit 1 ReadyToSwitchON
Bit 2 SwitchedON
Bit 3 Reserved
Bit 4 Trouble
Bit 5 Fault
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Fail CAN_Management
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
; Read access ; Write access CINH PLC STOP No transfer COM MOT