8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00942
752 L Firmware 05.00 - DMS 4.2 EN - 02/2010
C00942
C00950
C00951
C00952
Parameter | Name:
C00942 | L_ConvW conversion method
Data type: UNSIGNED_8
Index: 23633
d
= 5C51
h
As of version 04.00.00
Selection list
0 no conversion
1 from [%] into [incr./ms]
2from [incr./ms] into [%]
3Factors signed
4Factors unsigned
Subcodes Lenze setting Info
C00942/1 0: No conversion L_ConvW_1
: Conversion method
C00942/2 0: No conversion L_ConvW_2
: Conversion method
C00942/3 0: No conversion L_ConvW_3
: Conversion method
C00942/4 0: No conversion L_ConvW_4
: Conversion method
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00950 | L_Interpolator_1: Activation of the FB functions
Data type: UNSIGNED_8
Index: 23625
d
= 5C49
h
As of version 04.00.00
L_Interpolator_1
FB: Activation of signal interpolation and signal monitoring
Selection list
0No
1Yes
Subcodes Lenze setting Info
C00950/1 0: No Activation of signal interpolation
C00950/2 0: No Activation of signal monitoring
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00951 | L_Interpolator_1: Number of interpolation steps
Data type: UNSIGNED_16
Index: 23624
d
= 5C48
h
As of version 04.00.00
L_Interpolator_1
FB: Number of interpolation steps
Setting range (min. value | unit | max. value) Lenze setting
0 65535 1
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00952 | L_Interpolator_1: Limit value for error cycles
Data type: UNSIGNED_16
Index: 23623
d
= 5C47
h
As of version 04.00.00
L_Interpolator_1
FB: Limit value for missing data telegrams
Setting range (min. value | unit | max. value) Lenze setting
0 65535 5
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
efesotomasyon.com - Lenze

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze E84AVHC Series and is the answer not in the manual?

Lenze E84AVHC Series Specifications

General IconGeneral
BrandLenze
ModelE84AVHC Series
CategoryInverter Drive
LanguageEnglish

Related product manuals