8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00117
608 L Firmware 05.00 - DMS 4.2 EN - 02/2010
C00117
C00118
C00120
C00123
Parameter | Name:
C00117 | Status - brake output BD
Data type: UNSIGNED_8
Index: 24458
d
= 5F8A
h
Status message of brake output
Selection list (read only) Info
0 Inactive Brake output is inactive
1 Active Brake output is active
; Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00118 | DOx: Inversion
Data type: UNSIGNED_8
Index: 24457
d
= 5F89
h
Polarity of the digital outputs
Every digital output of the device can be inverted with regard to polarity via this bit field.
Digital output terminals
Setting range (min. hex value | max. hex value) Lenze setting
0x00 0xFF 0x00 (decimal: 0)
Value is bit-coded: (; =bit set) Info
Bit 0 Relay inverted Relay inversion
Bit 1 DO1 inverted Inversion of digital output 1
Bit 2 DO2 inverted Inversion of digital output 2
Bit 3 DO3 inverted Inversion of digital output 3
Bit 4 High current inverted Inversion of high-current output
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00120 | Motor overload threshold (I²xt)
Data type: INTEGER_16
Index: 24455
d
= 5F87
h
Operating threshold for the error message "OC6: Motor overload (I²xt)"
The response for reaching the threshold can be selected in C00606
.
The current thermal motor load is displayed in C00066
.
Setting range (min. value | unit | max. value) Lenze setting
0.00 % 250.00 100.00 %
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00123 | Device utilisat. threshold (Ixt)
Data type: INTEGER_16
Index: 24452
d
= 5F84
h
Operating threshold for the error message "OC5: Device overload (Ixt)"
The response for reaching the threshold can be selected in C00604
.
The current device utilisation is displayed in C00064
.
Setting range (min. value | unit | max. value) Lenze setting
0.00 % 200.00 100.00 %
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100