8400 HighLine | Parameter setting & configuration
I/O terminals
User-defined terminal assignment
246 L Firmware 05.00 - DMS 4.2 EN - 02/2010
6.5.1 Source-destination principle
The I/O configuration of the input and output signals is carried out according to the
source/destination principle:
A connection always has a direction and therefore always has a source and a target.
The inputs signals of the technology application are logically linked to the outputs of
system blocks which represent the device input terminals.
The inputs of system blocks that represent the device output terminals are logically
linked to output signals of the technology application.
The following graphic illustrates the source/destination principle:
[6-3] Source-destination principle
Note the following:
An equipment input terminal can be logically linked to several inputs of the application
block.
However, each input of the application block can only be logically linked to one input
signal.
An output of the application block can be logically linked to several equipment output
terminals.
n System blocks/ports on the input side of the equipment
o Logical links between the technology application and the input and output interfaces
p Technology application (selected with C00005)
q System blocks/ports on the output side of the equipment
LS_AnalogInput LS_AnalogOutput
LS_DigitalInput LS_DigitalOutput
Inputs Outputs
Input port
Analog inputs Analog Outputs
Digital Inputs Digital Outputs
Output port
Application
C00701 C00621
C00700 C00620