8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_Arithmetik_3
890 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
14.1.16 L_Arithmetik_3
This FB can combine two analog signals arithmetically.
The arithmetic function is selected in C00650/1
.
All internal intermediate results and the value output at the nOut_a output are
internally limited to ±32767.
Inputs
Outputs
Parameter
Identifier
Data type
Information/possible settings
nIn1_a
INT
Input signal 1
nIn2_a
INT
Input signal 2
Identifier
Data type
Value/meaning
nOut_a
INT
Output signal
• Internal limitation to ±32767 (±199.99 %)
Parameter Possible settings Info
C00650/1 Function selection
0
1
2
3
4 When the denominator has the
value "0", it will be set to "1".
5
/B$ULWKPHWLNB
Q,QBD Q2XWBD
Q,QBD
r
,Q
,Q,Q
,Q
,Q,Q
,Q,Q
,Q
_,Q_
,Q
2XW
,Q
,Q
&
Out_a nIn1_a=
Out_a nIn1_a nIn2_a+=
Out_a nIn1_a nIn2_a–=
nOut_a
nIn1_a nIn2_a⋅
16384
----------------------------------------=
nOut_a
nIn1_a
nIn2_a
-------------------- -
164⋅=
nOut_a
nIn1_a
16384 nIn2_a–
----------------------------------------
16384⋅=
efesotomasyon.com - Lenze