Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010 L 627
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00190
C00190
C00200
C00201
C00203
Parameter | Name:
C00190 | Setpoint arithmetic
Data type: UNSIGNED_8
Index: 24385
d
= 5F41
h
FB L_NSet_1: Selection of arithmetic
• For influencing the main setpoint (NSet) by an additive setpoint (NAdd).
Selection list (Lenze setting printed in bold)
0NOut = NSet
1 NOut = NSet + NAdd
2 NOut = NSet - NAdd
3 NOut = (NSet * NAdd) / 100%
4 NOut = (NSet * 1%) / |NAdd|
5 NOut = (NSet * 100%) / (100% - NAdd)
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00200 | Firmware product type
Data type: VISIBLE_STRING
Index: 24375
d
= 5F37
h
Display of the firmware product type
; Read access Write access CINH PLC STOP ; No transfer COM MOT
Parameter | Name:
C00201 | Firmware
Data type: VISIBLE_STRING
Index: 24374
d
= 5F36
h
Display of the firmware data of the control card and the power section
Subcodes Info
C00201/1 Firmware type contr. card
C00201/2 Firmware version contr. card
C00201/3 Firmware comp.date contr. card
C00201/4 Firmware type power section
C00201/5 Firmware version power section
C00201/6 Firmware comp.date power section
; Read access Write access CINH PLC STOP ; No transfer COM MOT
Parameter | Name:
C00203 | Product type code
Data type: VISIBLE_STRING
Index: 24372
d
= 5F34
h
Display of the single device component types
Subcodes Info
C00203/1 Type: Control card
C00203/2 Type: Power section
C00203/3 Type: MCI module
C00203/4 Reserved
C00203/5 Type: Memory module
C00203/6 Type: Safety card
C00203/7 Type: Standard device
C00203/8 Type: Complete device
C00203/9 Reserved
; Read access Write access CINH PLC STOP ; No transfer COM MOT