EasyManua.ls Logo

Lenze E84AVHC Series - C00800 | L_MPot_1: Upper limit; C00801 | L_MPot_1: Lower limit; C00802 | L_MPot_1: Acceleration time

Lenze E84AVHC Series
1118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware 05.00 - DMS 4.2 EN - 02/2010 L 705
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00762
C00762
C00765
C00766
C00767
C00800
C00801
C00802
C00761/44 0: Not connected LA_SwitchPos
: bFreeIn5
C00761/45 0: Not connected LA_SwitchPos
: bFreeIn6
C00761/46 0: Not connected LA_SwitchPos
: bFreeIn7
C00761/47 0: Not connected LA_SwitchPos
: bFreeIn8
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00761 | LA_SwitchPos: Digital connection list
Data type: UNSIGNED_16
Index: 23814
d
= 5D06
h
Parameter | Name:
C00762 | LA_SwitchPos: phi connection list
Data type: UNSIGNED_16
Index: 23813
d
= 5D05
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00765 | LA_SwitchPos_Out: Analog signal list
Data type: UNSIGNED_16
Index: 23810
d
= 5D02
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00766 | LA_SwitchPos_Out: Digital signal list
Data type: UNSIGNED_16
Index: 23809
d
= 5D01
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00767 | LA_SwitchPos_Out: phi signal list
Data type: UNSIGNED_16
Index: 23808
d
= 5D00
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00800 | L_MPot_1: Upper limit
Data type: INTEGER_16
Index: 23775
d
= 5CDF
h
FB L_MPot_1: Upper limit of the motor potentiometer function
Setting range (min. value | unit | max. value) Lenze setting
-199.99 % 199.99 100.00 %
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00801 | L_MPot_1: Lower limit
Data type: INTEGER_16
Index: 23774
d
= 5CDE
h
FB L_MPot_1: Lower limit of the motor potentiometer function
Setting range (min. value | unit | max. value) Lenze setting
-199.99 % 199.99 -100.00 %
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00802 | L_MPot_1: Acceleration time
Data type: UNSIGNED_16
Index: 23773
d
= 5CDD
h
FB L_MPot_1: Acceleration time of the motor potentiometer function
Setting range (min. value | unit | max. value) Lenze setting
0.1 s 6000.0 10.0 s
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10