EasyManuals Logo

Lenze E84AVHC Series User Manual

Lenze E84AVHC Series
1118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #989 background imageLoading...
Page #989 background image
Firmware 05.00 - DMS 4.2 EN - 02/2010 L 989
8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_Negation_2
14.1.88 L_Negation_2
This FB converts the sign of the input signal, i.e. the input signal is multiplied by the value
-1 and is then output.
With the value - 32768 at the nIn_a input, the value + 32767 is provided at the nOut_a
output.
Inputs
Outputs
Identifier
Data type
Value/meaning
nIn_a
INT
Input signal
Identifier
Data type
Value/meaning
nOut_a
INT
Output signal
/B1HJDWLRQB
Q,QBD Q2XWBD

efesotomasyon.com - Lenze

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze E84AVHC Series and is the answer not in the manual?

Lenze E84AVHC Series Specifications

General IconGeneral
BrandLenze
ModelE84AVHC Series
CategoryInverter Drive
LanguageEnglish

Related product manuals