8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_ComparePhi_2
910 L Firmware 05.00 - DMS 4.2 EN - 02/2010
14.1.28 L_ComparePhi_2
This FB compares two angle signals.
Comparison operation, hysteresis and window size can be parameterised.
Inputs
Outputs
Parameter
Identifier
Data type
Information/possible settings
dnIn1_p
DINT
Input signal 1
dnIn2_p
DINT
Input signal 2
Identifier
Data type
Value/meaning
bOut
BOOL
Status signal "Comparison statement is true"
TRUE The statement of the selected comparison mode is true.
Parameter Possible settings Info
C01670/2
Function selection
1 dnIn1 = dnIn2
2 dnIn1 > dnIn2
3 dnIn1 < dnIn2
4 |dnIn1| = |dnIn2|
5 |dnIn1| > |dnIn2|
6 |dnIn1| < |dnIn2|
C01671/2
0 Incr. 1073741824 Hysteresis
Lenze setting: 0 incr.
C01672/2
0 Incr. 1073741824 Window
Lenze setting: 0 incr.
For a detailed functional description see L_ComparePhi_1.
/B&RPSDUH3KLB
E2XW
& )XQFWLRQ
&
&
GQ,QBS
GQ,QBS
efesotomasyon.com - Lenze

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze E84AVHC Series and is the answer not in the manual?

Lenze E84AVHC Series Specifications

General IconGeneral
BrandLenze
ModelE84AVHC Series
CategoryInverter Drive
LanguageEnglish

Related product manuals