Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010 L 775
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C01233
C01233
C01234
C01235
Parameter | Name:
C01233 | MCK: Manual jog S-ramp time
Data type: UNSIGNED_16
Index: 23342
d
= 5B2E
h
S-ramp time for manual jog
•Setting "0 s" ≡ no rounding
Manual jog
Setting range (min. value | unit | max. value)
0.000 s 10.000
Subcodes Lenze setting Info
C01233/1 0.000 s Manual jog: S-ramp time
• S-ramp time for the manual speed ramps.
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000
Parameter | Name:
C01234 | MCK: Manual jog breakpoints
Data type: INTEGER_32
Index: 23341
d
= 5B2D
h
Breakpoint positions for manual jog
• The drive stops at the parameterised positions if they are in manual jog direction and breakpoint approaching
has been switched on in C01230
via bit 0.
Manual jog
Setting range (min. value | unit | max. value)
-214748.3647 unit 214748.3647
Subcodes Lenze setting Info
C01234/1 0.0000 unit Manual jog: Breakpoint 1
C01234/2 0.0000 unit Manual jog: Breakpoint 2
C01234/3 0.0000 unit Manual jog: Breakpoint 3
C01234/4 0.0000 unit Manual jog: Breakpoint 4
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C01235 | MCK: Manual jog waiting times
Data type: UNSIGNED_16
Index: 23340
d
= 5B2C
h
Waiting times for manual jog
Manual jog
Setting range (min. value | unit | max. value)
0.000 s 65.000
Subcodes Lenze setting Info
C01235/1 5.000 s Waiting time 2nd speed
• Time after which the drive accelerates from the first
manual speed (C01231/1
) to the second manual
speed (C01231/2
).
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000