Parameter reference
Parameter list | C00309
636 L Firmware 05.00 - DMS 4.2 EN - 02/2010
C00309
C00310
C00311
C00313
C00314
C00315
C00316
C00317
C00320
C00321
Parameter | Name:
C00309 | PartitionSel
Data type: UNSIGNED_8
Index: 24266
d
= 5ECA
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00310 | PartitionValue
Data type: UNSIGNED_16
Index: 24265
d
= 5EC9
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00311 | Runtime measurement
Data type: UNSIGNED_32
Index: 24264
d
= 5EC8
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00313 | LS_DataAccess: activation
Data type: UNSIGNED_8
Index: 24262
d
= 5EC6
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00314 | LS_DataAccess: address access
Data type: UNSIGNED_32
Index: 24261
d
= 5EC5
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00315 | SystemFail-Adr
Data type: UNSIGNED_32
Index: 24260
d
= 5EC4
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00316 | SystemFail-Info
Data type: UNSIGNED_16
Index: 24259
d
= 5EC3
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00317 | WatchdogTimeMax
Data type: UNSIGNED_16
Index: 24258
d
= 5EC2
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00320 | Debug information
Data type: UNSIGNED_32
Index: 24255
d
= 5EBF
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00321 | Main program runtime
Data type: UNSIGNED_16
Index: 24254
d
= 5EBE
h
Display of the current and the maximum runtime of the main program in the controller
Setting range (min. value | unit | max. value)
0 ms 65535
Subcodes Lenze setting Info
C00321/1 0 ms Curr. runtime of main program
C00321/2 0 ms Max. runtime of main program
; Read access ; Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 1
efesotomasyon.com - Lenze

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze E84AVHC Series and is the answer not in the manual?

Lenze E84AVHC Series Specifications

General IconGeneral
BrandLenze
ModelE84AVHC Series
CategoryInverter Drive
LanguageEnglish

Related product manuals