Firmware 05.00 - DMS 4.2 EN - 02/2010 L 669
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00567
C00567
C00569
C00570
C00572
Parameter | Name:
C00567 | Speed controller resp. limited
Data type: UNSIGNED_8
Index: 24008
d
= 5DC8
h
Response for limitation of the speed controller output (bLimSpeedCtrlOut =TRUE)
Selection list (Lenze setting printed in bold)
0No Reaction
1Fault
5 Warning
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00569 | Resp. to peak current
Data type: UNSIGNED_8
Index: 24006
d
= 5DC6
h
Configuration of monitoring of the motor control (group 1)
Selection list
0 No Reaction
1Fault
5 Warning
Subcodes Lenze setting Info
C00569/1 0: No Reaction Response for overcurrent detection and clamp operation
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00570 | Resp. to controller limitations
Data type: UNSIGNED_8
Index: 24005
d
= 5DC5
h
Configuration of monitoring of the motor control (group 2)
Selection list
0 No Reaction
1Fault
5 Warning
Subcodes Lenze setting Info
C00570/1 0: No Reaction Response for limitation in the direct-axis current
controller
e.g. for SC (servo control) mode
C00570/2 0: No Reaction Response to limitation in the cross current controller
e.g. for SC (servo control) mode
C00570/3 0: No Reaction Response for limitation of the torque setpoint
Limitation of the speed controller output, the
differential setpoint precontrol, and of the additive
torque for SC (servo control) and SLVC (vector control)
modes.
C00570/4 0: No Reaction Response for limitation in the field controller
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00572 | Brake resistor overload threshold
Data type: UNSIGNED_8
Index: 24003
d
= 5DC3
h
As of version 02.00.00
Adjustable threshold for monitoring the brake resistor utilisation
The response for reaching the threshold can be selected in C00574
.
Setting range (min. value | unit | max. value) Lenze setting
0 % 100 100 %
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT Scaling factor: 1