Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010 L 669
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00567
C00567
C00569
C00570
C00572
Parameter | Name:
C00567 | Speed controller resp. limited
Data type: UNSIGNED_8
Index: 24008
d
= 5DC8
h
Response for limitation of the speed controller output (bLimSpeedCtrlOut =TRUE)
Selection list (Lenze setting printed in bold)
0No Reaction
1Fault
5 Warning
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00569 | Resp. to peak current
Data type: UNSIGNED_8
Index: 24006
d
= 5DC6
h
Configuration of monitoring of the motor control (group 1)
Selection list
0 No Reaction
1Fault
5 Warning
Subcodes Lenze setting Info
C00569/1 0: No Reaction Response for overcurrent detection and clamp operation
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00570 | Resp. to controller limitations
Data type: UNSIGNED_8
Index: 24005
d
= 5DC5
h
Configuration of monitoring of the motor control (group 2)
Selection list
0 No Reaction
1Fault
5 Warning
Subcodes Lenze setting Info
C00570/1 0: No Reaction Response for limitation in the direct-axis current
controller
• e.g. for SC (servo control) mode
C00570/2 0: No Reaction Response to limitation in the cross current controller
• e.g. for SC (servo control) mode
C00570/3 0: No Reaction Response for limitation of the torque setpoint
• Limitation of the speed controller output, the
differential setpoint precontrol, and of the additive
torque for SC (servo control) and SLVC (vector control)
modes.
C00570/4 0: No Reaction Response for limitation in the field controller
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00572 | Brake resistor overload threshold
Data type: UNSIGNED_8
Index: 24003
d
= 5DC3
h
As of version 02.00.00
Adjustable threshold for monitoring the brake resistor utilisation
• The response for reaching the threshold can be selected in C00574
.
Setting range (min. value | unit | max. value) Lenze setting
0 % 100 100 %
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT Scaling factor: 1