8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_SignalMonitor_b
1050 L Firmware 05.00 - DMS 4.2 EN - 02/2010
14.1.128 L_SignalMonitor_b
This FB outputs four binary signals which can be selected from a list of binary output
signals of all function blocks provided in the device.
Inversion of the output signals can be set.
Outputs
Parameter
Identifier
Data type
Value/meaning
bOut1
...
bOut4
BOOL
Output signal
FALSE / TRUE
Parameter Possible settings Info
C00411/1
...
C00411/4
Selection of the signal sources for
bOut1 ... bOut4
0Not connected
1000 LA_nCtrl_bDriveReady
1001 LA_nCtrl_bDriveFail
1002 LA_nCtrl_bCInhActive
.. ...
42033 LA_NCtrl_bPIDIOff
C00412
Inversion
Bit set = inversion active
Bit 0 bOut1 inverted
Bit 1 bOut2 inverted
Bit 2 bOut3 inverted
Bit 3 bOut4 inverted
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
/B6LJQDO0RQLWRUBE
E2XW
& &%LW
&
&
&
E2XW
&%LW
E2XW
&%LW
E2XW
&%LW