8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C01295
782 L Firmware 05.00 - DMS 4.2 EN - 02/2010
C01295
C01296
C01297
Parameter | Name:
C01295 | L_MCKStateInterface_1: Position selection
Data type: UNSIGNED_8
Index: 23280
d
= 5AF0
h
As of version 04.00.00
Selection of the position to be output at the dnPosOut_p output of the L_MckStateInterface
FB
Selection list (Lenze setting printed in bold)
0dnPosIn_p
1 Current feed
2dnSetPos_p
3 dnActPos_p
4dnDeltaPos_p
5dnTargetPos_p
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01296 | Mode: Position calculation
Data type: UNSIGNED_8
Index: 23279
d
= 5AEF
h
As of version 04.00.00
MCKInterface
Selection list
0 dnPosOut_p=dnPosIn_p
1 16 bits: LW=+/-32767
2 16 bits: HW=+/-; LW=0..65535
3 32 bits: HW_LW=+/-214748_3647
Subcodes Lenze setting Info
C01296/1 0: dnPosOut_p=dnPosIn_p PosCalcMode: L_MCKCtrlInterface_1
C01296/2 1: 16Bit: LW=+/-32767 PosDisplayMode: L_MCKStateInterface_1
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01297 | Alternative function
Data type: UNSIGNED_8
Index: 23278
d
= 5AEE
h
Selection of the alternative function for bit 16 (PosExecute) in the MCK control word
Alternative functions for control bit "PosExecute"
Setting range (min. hex value | max. hex value) Lenze setting
0x00 0xFF 0x03 (decimal: 3)
Value is bit-coded: (; =bit set) Info
Bit 0 ; PosStop with PosExecute = FALSE "1" Stop positioning with PosExecute
PosExecute="0" stops a running positioning process
by ramp-down to standstill.
Bit 1 ; HomingStartStop with PosExecute "1" Start/stop homing with PosExecute
PosExecute="1" starts homing, PosExecute="0" stops
homing in the "Homing" mode.
Bit 2 SetProfilPosition with PosExecute "1" Teach set position with PosExecute
PosExecute="0->1" accepts the setpoint position at
the MCK in the profile with the specified profile
number.
Bit 3 Automatic acceptance of
SetProfilPosition
; Read access ; Write access CINH PLC STOP No transfer COM MOT