Firmware 05.00 - DMS 4.2 EN - 02/2010 L 429
8400 HighLine | Parameter setting & configuration
Basic drive functions (MCK)
Positioning
8.8.4.6 "Transient phenomenon active" status
Bit 16 in the MCK status word
or the bDwellTime output of the L_MckStateInterface FB is
set when the setpoint position has been reached after the settling time set in C01244/1
has expired. The status detects the time after the bDone signal when settling to target
position is executed and actual position detection is not active yet. That way, mechanical
transient phenomena of the tool can be taken into account when reaching the target
position.
[8.3] Definition of the settling time
n Actual value profile
o Setpoint profile
t [s]
v [m/s]
t [s]
bDone
TRUE
FALSE
t [s]
bDwellTime
TRUE
FALSE
Dwell time
C01244/1
Parameter Info Lenze setting
Value Unit
C01244/1 MCK: Dwell time - target position 100 ms