Firmware 05.00 - DMS 4.2 EN - 02/2010 L 607
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00114
C00114
C00115
Parameter | Name:
C00114 | DIx: Polarity
Data type: UNSIGNED_16
Index: 24461
d
= 5F8D
h
Polarity of the digital inputs
Every digital input of the device can be inverted with regard to polarity via this bit field.
Digital input terminals
Setting range (min. hex value | max. hex value) Lenze setting
0x0000 0xFFFF 0x0000 (decimal: 0)
Value is bit-coded: (; =bit set) Info
Bit 0 Invert. DI1 Inversion of digital input 1
Bit 1 Invert. DI2 Inversion of digital input 2
Bit 2 Invert. DI3 Inversion of digital input 3
Bit 3 Invert. DI4 Inversion of digital input 4
Bit 4 Invert. DI5 Inversion of digital input 5
Bit 5 Invert. DI6 Inversion of digital input 6
Bit 6 Invert. DI7 Inversion of digital input 7
Bit 7 Reserve
Bit 8 Reserve
Bit 9 Reserve
Bit 10 Reserve
Bit 11 Reserve
Bit 12 Reserve
Bit 13 Reserve
Bit 14 Reserve
Bit 15 Invert CInh Inversion of digital input CINH (controller inhibit)
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00115 | DI 1/2 & 6/7: Function
Data type: UNSIGNED_8
Index: 24460
d
= 5F8C
h
Function assignment of the digital terminals DI1/2 and DI6/7
Digital input terminals
: Function assignment
Selection list Info
0 DI1(6)=In / DI2(7)=In DI1/6 = digital input
DI2/7 = digital input
1 DI1(6)=FreqIn / DI2(7)=In DI1/6 = 1-track frequency input
DI2/7 = digital input
2 DI1(6)&DI2(7)=FreqIn (2-track) DI1/6 and DI2/7 = 2-track frequency input
3 DI1(6)=FreqIn / DI2(7)=direction DI1/6 = 1-track frequency input
DI2/7 = specification of direction
4 DI1(6)=CountIn / DI2(7)=In DI1/6 = counter input
DI2/7 = digital input
Subcodes Lenze setting Info
C00115/1 0: DI1(6)=In / DI2(7)=In Function assignment of DI1 and DI2
C00115/2 0: DI1(6)=In / DI2(7)=In Function assignment of DI6 and DI7
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1