EasyManua.ls Logo

Lenze E84AVHC Series - C00339 | L_Arithmetik_2: Function; C00341 | CAN Management: Error configuration

Lenze E84AVHC Series
1118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00339
638 L Firmware 05.00 - DMS 4.2 EN - 02/2010
C00339
C00341
Parameter | Name:
C00339 | L_Arithmetik_2: Function
Data type: UNSIGNED_8
Index: 24236
d
= 5EAC
h
FB L_Arithmetik_2: Selection of the internal arithmetic
Selection list (Lenze setting printed in bold)
0nOut_a = nIn1_a
1 nOut_a = nIn1_a + nIn2_a
2 nOut_a = nIn1_a - nIn2_a
3 nOut_a = (nIn1_a * nIn2_a) / 100%
4 nOut_a = (nIn1_a * 1%) / |nIn2_a|
5 nOut_a = (nIn1_a * 100%) / (100% -
nIn2_a)
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00341 | CAN Management: Error configuration
Data type: UNSIGNED_16
Index: 24234
d
= 5EAA
h
As of version 04.00.00
Selection of the events for which the bFail error output of the LS_CANMAnagement
SB must be set to TRUE.
Setting range (min. hex value | max. hex value) Lenze setting
0x0000 0xFFFF 0x0000 (decimal: 0)
Value is bit-coded: (; =bit set)
Bit 0 BusOff_MsgErr
Bit 1 Warning
Bit 2 NodeStopped
Bit 3 HeartBeatEvent
Bit 4 CAN1_In_Monitor.
Bit 5 CAN2_In_Monitor.
Bit 6 CAN3_In_Monitor.
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
; Read access ; Write access CINH PLC STOP No transfer COM MOT