8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00339
638 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
C00339
C00341
Parameter | Name:
C00339 | L_Arithmetik_2: Function
Data type: UNSIGNED_8
Index: 24236
d
= 5EAC
h
FB L_Arithmetik_2: Selection of the internal arithmetic
Selection list (Lenze setting printed in bold)
0nOut_a = nIn1_a
1 nOut_a = nIn1_a + nIn2_a
2 nOut_a = nIn1_a - nIn2_a
3 nOut_a = (nIn1_a * nIn2_a) / 100%
4 nOut_a = (nIn1_a * 1%) / |nIn2_a|
5 nOut_a = (nIn1_a * 100%) / (100% -
nIn2_a)
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00341 | CAN Management: Error configuration
Data type: UNSIGNED_16
Index: 24234
d
= 5EAA
h
As of version 04.00.00
Selection of the events for which the bFail error output of the LS_CANMAnagement
SB must be set to TRUE.
Setting range (min. hex value | max. hex value) Lenze setting
0x0000 0xFFFF 0x0000 (decimal: 0)
Value is bit-coded: (; =bit set)
Bit 0 BusOff_MsgErr
Bit 1 Warning
Bit 2 NodeStopped
Bit 3 HeartBeatEvent
Bit 4 CAN1_In_Monitor.
Bit 5 CAN2_In_Monitor.
Bit 6 CAN3_In_Monitor.
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
; Read access ; Write access CINH PLC STOP No transfer COM MOT