Firmware 05.00 - DMS 4.2 EN - 02/2010 L 773
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C01227
C01227
C01228
C01229
Parameter | Name:
C01227 | MCK: Ref. positions
Data type: INTEGER_32
Index: 23348
d
= 5B34
h
Positions for determining the zero position of the reference measuring system
Homing
Setting range (min. value | unit | max. value)
-214748.3647 unit 214748.3647
Subcodes Lenze setting Info
C01227/1 0.0000 unit MCK: Ref. offset reference degree
Relative traverse path by which the drive traverses
after detection of the reference initiator.
C01227/2 0.0000 unit MCK: Ref. home position
Position with which setpoint and actual position are
loaded after completion of homing.
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C01228 | MCK: Ref. sequence profile
Data type: UNSIGNED_8
Index: 23347
d
= 5B33
h
Number of the sequence profile the absolute position of which will be approached after homing.
Homing
Setting range (min. value | unit | max. value) Lenze setting
0150
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01229 | MCK: Position limiting values
Data type: INTEGER_32
Index: 23346
d
= 5B32
h
Software limit position for limiting the valid traversing range
The error response for leaving the valid traversing range can be parameterised in C00595/3
and C00595/4.
Note:
For limiting the traversing range by means of software limit positions, the home position must be known and the
positive software limit position must be higher than the negative software limit position!
Limit position monitoring
Setting range (min. value | unit | max. value)
-214748.3647 units 214748.3647
Subcodes Lenze setting Info
C01229/1 0.0000 units MCK: Positive SW limit position
(positive travel range limit)
C01210/2 0.0000 units MCK: Negative SW limit position
(negative travel range limit)
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000