Firmware 05.00 - DMS 4.2 EN - 02/2010 L 993
8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_NLim_2
14.1.90 L_NLim_2
This FB can mask out up to three parameterisable blocking zones within a continuous
signal characteristic.
Inputs
Outputs
Note!
A value of "0" cannot be masked out if the nIn_a input signal changes signs.
Identifier
Data type
Information/possible settings
bEnable
BOOL
Activate zone masking
FALSE The FB has been deactivated.
The input signal is output one-to-one at the nOut_a output.
TRUE The FB has been activated.
Zone masking of the input signal is carried out according to the
parameterised blocking zones.
nIn_a
INT
Input signal
Identifier/data type Value/meaning
wState
WORD
Bit-coded status word
Bits that are not listed are reserved for future extensions.
Bit 0 No blocking zone active
Bit 1 Blocking zone 1 active
Bit 2 Blocking zone 2 active
Bit 3 Blocking zone 3 active
nOut_a
INT
Output signal
If the FB has been activated, the output signal is outside the blocking zones.
bLimitActive
BOOL
"Limitation active" status signal
TRUE The input signal is inside a blocking zones and is limited to the
respective boundary value of the blocking zone.
/B1/LPB
E(QDEOH Z6WDWH
Q,QBD Q2XWBD
E/LPLW$FWLYH
&
&