Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010 L 109
8400 HighLine | Parameter setting & configuration
Motor control (MCTRL)
Defining current and speed limits
 
5.3 Defining current and speed limits
Limitation of the speed setpoint
Parameterising the reference speed in C00011
 means that the drive must rotate at the set
speed if a speed setpoint of 100% is specified.
All speed setpoint selections are provided in % and always refer to the reference speed set
in C00011
.
 Tip!
For reasons of achievable resolution and the accuracy involved, the reference
speed should be geared to the speed range required for the respective application.
Lenze recommendation: Reference speed (C00011
) = 1500 ... 3000 rpm
Irrespective of the operating mode, there are more limitation options:
Parameter Info Lenze setting
Value Unit
C00909/1 Max. positive speed 120 %
C00909/2
Max. negative speed 120 %
C00910/1
Max. positive output frequency 1000 Hz
C00910/2
Max. negative output frequency 1000 Hz
 Note!
In the torque-controlled operation (bTorquemodeOn = TRUE), the limitation of 
the speed setpoint does not have any effect! In this case, a permissible speed 
range can be defined via speed limitation (nSpeedHighLimit and 
nSpeedLowLimit).