8400 HighLine | Parameter setting & configuration
Function library
System blocks | LS_WriteParamList
1096 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
is finally used is dependent upon the assignment of the two bSelectWriteValue_1 and
bSelectWriteValue_2 inputs:
14.2.26.3 Activating the writing of the parameters
Depending on the selection in C01082
, the writing of the parameter list is activated by a
FALSE/TRUE edge at the bExecute input or if a change is made at the select inputs. The
parameters are written one at a time every time the main program is executed until the
entire parameter list is processed.
After successful completion
... the bDone output is set to TRUE.
The bDone output is automatically reset to FALSE if writing via bExecute is activated
again.
In the event of an error
... the bDone output remains set to FALSE and the bFail output is set to TRUE.
C01083
displays an error status and C01084 displays the number of the list entry at
which the error occurred (in connection with the selected value set).
If several errors occur at the same time, only the first incorrect list entry will be
displayed. Hence, after elimination of the displayed error and another activation, more
errors may be displayed.
The parameter list will always be processed from beginning to end, even if errors occur
in the meantime.
bSelectWriteValue_1 bSelectWriteValue_2 Value set used
FALSE FALSE Value set 1 (C01086/1 ... n
)
TRUE FALSE Value set 2 (C01087/1 ... n
)
FALSE TRUE Value set 3 (C01088/1 ... n
)
TRUE TRUE Value set 4 (C01089/1 ... n
)