Firmware 05.00 - DMS 4.2 EN - 02/2010 L 231
8400 HighLine | Parameter setting & configuration
I/O terminals
Digital output terminals
6.2 Digital output terminals
The drive controller has
three parameterisable output terminals (DO1 ... DO3) for outputting digital signals
a relay output (terminal strip X101),
a (high-current) output for controlling a brake (terminal strip X107).
Parameterisation dialog in the »Engineer«:
Note!
Initialisation behaviour:
After mains switching up to the start of the application, the digital outputs
remain set to FALSE.
Exception handling:
In case of a critical exception in the application (e.g. reset), the digital outputs
are set to FALSE considering the terminal polarity parameterised in C00118
.
Switching cycle diagnostics of the relay:
A reference for evaluating the wear limit can be obtained via the number of
switching cycles of the relay displayed in C00177/2
.