8400 HighLine | Parameter setting & configuration
I/O terminals
Digital input terminals
230 L Firmware 05.00 - DMS 4.2 EN - 02/2010
Inputs
Outputs
Identifier
DIS code | data type
Information/possible settings
Counting input DI1 Using DI1(6) as counting input
bCountIn1_ResetCompare
BOOL
Reset status signal "Comparison value reached"
FALSEÊTRUE The output bCountIn1_Compare is reset to FALSE.
bCountIn1_LoadStartValue
BOOL
Load starting value into counter
FALSEÊTRUE The starting value set in C02840/1
is accepted as the current count
value.
Counting input DI6 Using DI1(6) as counting input
bCountIn6_ResetCompare
BOOL
Reset status signal "Comparison value reached"
FALSEÊTRUE The output bCountIn6_Compare is reset to FALSE.
bCountIn6_LoadStartValue
BOOL
Load starting value into counter
FALSEÊTRUE The starting value set in C02840/3
is accepted as the current count
value.
Identifier
DIS code | data type
Value/meaning
bCInh
C00443/2 | BOOL
RFR digital input (controller enable)
Digital inputs DI1 ... DI7 Using DI1(6) and DI2(7) as digital inputs
bIn1 ... bIn7
C00443/2 | BOOL
Digital input DI1 ... DI7
Counting input DI1 Using DI1(6) as counting input
bCountIn1_Compare
BOOL
Status signal "Comparison value reached"
FALSE Current count value < comparison value (C02840/2
)
TRUE Current count value comparison value (C02840/2
)
wCountIn1_HW
wCountIn1_LW
C02841/1 | WORD
Current count value
Output as High and Low word (without sign)
Possible counting range: 0 ... 2
31
-1
Frequency input DI1/DI2 Using DI1(6) and DI2(7) as frequency inputs
nFreqIn12_a
C00446/1 | INT
Output frequency as scaled analog signal in [%]
nFreqIn12_v
C00445/1 | INT
Output frequency as speed signal in [inc/ms]
Counting input DI6 Using DI1(6) as counting input
bCountIn1_Compare
BOOL
Status signal "Comparison value reached"
FALSE Current count value < comparison value (C02840/4
)
TRUE Current count value comparison value (C02840/4
)
wCountIn6_HW
wCountIn6_LW
C02841/2 | WORD
Current count value
Output as High and Low word (without sign)
Possible counting range: 0 ... 2
31
-1
Frequency input DI6/DI7 Using DI1(6) and DI2(7) as frequency inputs
nFreqIn67_a
C00446/2 | INT
Output frequency as scaled analog signal in [%]
nFreqIn67_v
C00445/2 | INT
Output frequency as speed signal in [inc/ms]