Firmware 05.00 - DMS 4.2 EN - 02/2010 L 707
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00807
C00807
C00808
C00809
C00810
Parameter | Name:
C00807 | L_NLim_1: Max.SkipFrq.
Data type: INTEGER_16
Index: 23768
d
= 5CD8
h
L_NLim_1 FB: Maximum blocking frequencies
Setting range (min. value | unit | max. value)
0.00 % 199.99
Subcodes Lenze setting Info
C00807/1 0.00 % Maximum blocking frequency for zone 1
C00807/2 0.00 % Maximum blocking frequency for zone 2
C00807/3 0.00 % Maximum blocking frequency for zone 3
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00808 | L_NLim_1: Min.SkipFrq.
Data type: INTEGER_16
Index: 23767
d
= 5CD7
h
L_NLim_1 FB: Minimum blocking frequencies
Setting range (min. value | unit | max. value)
0.00 % 199.99
Subcodes Lenze setting Info
C00808/1 0.00 % Minimum blocking frequency for zone 1
C00808/2 0.00 % Minimum blocking frequency for zone 2
C00808/3 0.00 % Minimum blocking frequency for zone 2
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00809 | L_NLim_2: Max.SkipFrq.
Data type: INTEGER_16
Index: 23766
d
= 5CD6
h
L_NLim_2 FB: Maximum blocking frequencies
Setting range (min. value | unit | max. value)
0.00 % 199.99
Subcodes Lenze setting Info
C00809/1 0.00 % Maximum blocking frequency for zone 1
C00809/2 0.00 % Maximum blocking frequency for zone 2
C00809/3 0.00 % Maximum blocking frequency for zone 3
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00810 | L_NLim_2: Min.SkipFrq.
Data type: INTEGER_16
Index: 23765
d
= 5CD5
h
L_NLim_2 FB: Minimum blocking frequencies
Setting range (min. value | unit | max. value)
0.00 % 199.99
Subcodes Lenze setting Info
C00810/1 0.00 % Minimum blocking frequency for zone 1
C00810/2 0.00 % Minimum blocking frequency for zone 2
C00810/3 0.00 % Minimum blocking frequency for zone 3
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100