EasyManua.ls Logo

Lenze E84AVHC Series - C00488 | L_JogCtrlEdgeDetect_1; C00490 | Position encoder selection; C00495 | Speed sensor selection

Lenze E84AVHC Series
1118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware 05.00 - DMS 4.2 EN - 02/2010 L 665
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00488
C00488
C00490
C00495
Parameter | Name:
C00488 | L_JogCtrlEdgeDetect_1
Data type: UNSIGNED_8
Index: 24087
d
= 5E17
h
As of version 02.00.00
FB L_JogCtrlExtension_1
: Signal methodology
Selection whether the corresponding function is to be activated by edge or level.
Selection list
0 Level
1Edge
Subcodes Lenze setting Info
C00488/1 0: Level InputSens.SlowDown1
Selection of edge or level for starting slow-down
function 1
C00488/2 0: Level InputSens.Stop1
Selection of edge or level for stop function 1
C00488/3 0: Level InputSens.SlowDown2
Selection of edge or level for starting slow-down
function 2
C00488/4 0: Level InputSens.Stop2
Selection of edge or level for stop function 2
C00488/5 0: Level InputSens.SlowDown3
Selection of edge or level for starting slow-down
function 3
C00488/6 0: Level InputSens.Stop3
Selection of edge or level for stop function 3
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00490 | Position encoder selection
Data type: UNSIGNED_8
Index: 24085
d
= 5E15
h
Selection of the feedback system for the generation of the actual position on the load
Encoder/feedback system
Selection list (Lenze setting printed in bold) Info
0 No sensor No encoder available on the load
1 Sensor signal FreqIn12 Position encoder signal is fed via digital inputs DI1 and
DI2
2 Encoder signal FreqIn67 Position encoder signal is fed via digital inputs DI6 and
DI7
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00495 | Speed sensor selection
Data type: UNSIGNED_8
Index: 24080
d
= 5E10
h
Selection of the feedback system for the actual speed for motor control and display
Encoder/feedback system
Selection list (Lenze setting printed in bold) Info
0 No sensor No encoder available for the actual speed detection
1 Sensor signal FreqIn12 Speed encoder signal is fed via digital inputs DI1 and DI2
2 Encoder signal FreqIn67 Speed encoder signal is fed via digital inputs DI6 and DI7
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1