Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010 L 275
8400 HighLine | Parameter setting & configuration
Technology applications
TA "Actuating drive speed"
7.4.3.1 Terminals 0
Connection Assignment Connection Assignment
X101/NC-NO LA_NCtrl.bDriveFail
X5/RFR LA_NCtrl.bFailReset X3/A1U LA_NCtrl.nMainSetValue_a *
X5/DI1 LA_NCtrl.bJogSpeed1 X3/A1I -
X5/DI2 LA_NCtrl.bJogSpeed2 X3/A2U -
X5/DI3 LA_NCtrl.bSetDCBrake X3/A2I -
X5/DI4 LA_NCtrl.bSetSpeedCcw X3/O1U LA_NCtrl.nMotorSpeedAct_a *
X5/DI5 - X3/O1I -
X5/DI6 - X3/O2U -
X5/DI7 - X3/O2I -
* 10V ≡ 100% of reference speed (C00011
)
X107/BD1 - X4/DO1 LA_NCtrl.bDriveReady
X107/BD2 - X4/DO2 -
X4/DO3 -
X5
A2I
AR
COM
A1U
NC
A2U
A1I
NO
X107 X4
X3
DI3
DI2
DI4
DI5
DI6
DI7
GI
24I
DI1
RFR
24B 24O
GB DO1
BD2 DO3
GO
BD1 DO2
GA
O1U
O1I
O2U
O2I
X101
24E
+
=
DriveFail
CG
CL
CH
X1
DriveReady
Controller enable
External
supply
24VDC
Fixed setpoint 1
Fixed setpoint 2
DC brake
Direction of rotation CCw
Actual spe
Speed setp
efesotomasyon.com - Lenze