Firmware 05.00 - DMS 4.2 EN - 02/2010 L 1059
8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_SRFG_2
Parameter
Parameter Possible settings Info
C01040/2
0.001 s 999.999 Acceleration/Deceleration time
Initialisation: 100.000 s
C01041/2
0.001 s 50.000 S-ramp time
Initialisation: 0.200 s
C01042/3
(from version 05.00.00)
-199.99 s 199.99 Pos. limit
Initialisation: 100.00 %
C01042/4
(from version 05.00.00)
-199.99 s 199.99 Neg. limit
Initialisation: -100.00 %
For a detailed functional description see L_SRFG_1.