Firmware 05.00 - DMS 4.2 EN - 02/2010 L 135
8400 HighLine | Parameter setting & configuration
Motor control (MCTRL)
Sensorless vector control (SLVC)
The implementation of torque-actuated operation with speed limitation
The limitation of the maximum torque in motor and generator mode for speed-
actuated operation
Short overview of the relevant parameters:
Parameter Info
C00006
Selection of the 4 operating mode:"SLVC: Vector control"
C00011
Reference speed
C00018
Switching frequency
C00021
Slip compensation
C00022
Current limit (in motor mode)
C00023
Current limit (in generator mode)
C00057
Maximum torque
C00070/1
SLVC: V
p
speed controller
C00071/1
SLVC: T
i
speed controller
C00073/2
SLVC: V
p
torque controller
C00074/2
SLVC: T
i
torque controller
C00080
Override point of field weakening function
C00081
Rated motor power
C00082
Motor rotor resistance
C00083
Motor rotor time constant
C00084
Motor stator resistance
C00085
Motor stator leakage inductance
C00087
Rated motor speed
C00088
Rated motor current
C00089
Rated motor frequency
C00090
Rated motor voltage
C00091 Motor cosine phi
C00092
Motor magnetising inductance
C00095
Motor magnetising current
C00097 Rated motor torque
C00273
Total moment of inertia
C00275
Setpoint precontrol filtering
C00909/1
Maximum positive speed
C00909/2
Maximum negative speed
C00910/1
Maximum positive output frequency
C00910/2
Maximum negative output frequency
C00915
Motor cable length
C00916
Motor cable cross-section
C00917 Motor cable resistance
C00985
Feedforward control in the d-branch
C00986
Feedforward control in the q-branch
Highlighted in grey = display parameter