Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010 L 163
8400 HighLine | Parameter setting & configuration
Motor control (MCTRL)
Servo control (SC)
Field controller
The field controller is designed as a PI controller.
The gain Vp (C00077
) of the field controller can be calculated using the motor rotor time
constant and the equivalent time constant of the current-controlled motor:
If the rated data of the motor and the mass inertia of the drive system are known, we
recommend the following setting:
[5-19] Recommendation for the setting of the gain and the time constant of the field controller
Tip!
The motor rotor time constant depends on the motor rotor resistance, the
magnetising inductance, and the leakage inductance.
• For an optimal calculation, we recommend to select the motor from the motor
catalogue of the »Engineer« first if a Lenze motor is used. Selecting a motor
from the motor catalogue in the »Engineer« ( 100)
• If a third party manufacturer's motor is used, motor parameter identification
must be carried out previously. Automatic motor data identification
( 102)
Parameter Info Lenze setting
Value Unit
C00077 SC: Vp field controller 12.80
C00078
SC: Tn field controller 256.0 ms
V
PField
: Gain of the field controller (C00077)
T
R
: Motor rotor time constant (C00083)
T
Equi
: Motor equivalent time constant
V
PField
: Gain of the field controller (C00077)
T
R
: Motor rotor time constant (C00083)
T
Equi
: Motor equivalent time constant
T
NField
: Time constant of the field controller (C00078)
V
PFeld
T
R
s[]
T
Ersatz
ms[]
------------------------------ -
%[]=
V
PFeld
T
R
s[]
4T
Ersatz
ms[]⋅
--------------------------------------
T
R
s[]
001s[],
--------------------=≈
T
NFeld
ms[]T
R
ms[]=