8400 HighLine | Parameter setting & configuration
Technology applications
TA "Actuating drive speed"
268 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
 
nMainSetValue_a
INT
Main speed setpoint
 • Offset and gain of this input signal can be set in C00696
 and C00670 for a simple 
signal adjustment of a setpoint encoder.
 • Scaling: 16384 ≡ 100 % rated speed (C00011
)
 • The main setpoint is transformed to a speed setpoint in the setpoint encoder via 
a ramp function generator with linear or S-shaped ramps.
 • Upstream to the ramp function generator, a blocking speed masking function 
and a setpoint MinMax limitation are effective.
 • For a detailed functional description see FB L_NSet
.
nAuxSetValue_a
INT
Additional speed setpoint
 • The additional speed setpoint can be linked arithmetically with the main speed 
setpoint behind the ramp function generator.
 • You must set the setpoint arithmetic to "1: NOut = NSet + NAdd" in C00190
 in 
order to activate the additional speed setpoint.
 • Offset and gain of this input signal can be adjusted in C00697
 and C00671 for a 
simple adjustment of a setpoint encoder.
 • Scaling: 16384 ≡ 100 % rated speed (C00011
)
 • The acceleration and deceleration time for the additional speed setpoint can be 
set in C00220
 and C00221.
 • For a detailed functional description see FB L_NSet
.
bJogSpeed1
bJogSpeed2
BOOL
Selection inputs for fixed changeover setpoints (JOG setpoints) for the main setpoint
 • A fixed setpoint for the setpoint generator can be activated instead of the main 
setpoint via these selection inputs.
 • The four selection inputs are binary coded, therefore 15 fixed setpoints can be 
selected.
 • In the case of binary coded selection "0" (all inputs = FALSE or not assigned), main 
setpoint nMainSetValue_a is active.
 • The selection of the fixed setpoints is carried out in C00039/1...15
 in [%] based on 
the reference speed (C00011
).
 • For a detailed functional description see FB L_NSet
.
bJogSpeed4
bJogSpeed8
BOOL
bJogRamp1
bJogRamp2
BOOL
Selection inputs for alternative acceleration/deceleration times for the main 
setpoint
 • The four selection inputs are binary coded, therefore 15 alternative acceleration/
deceleration times can be selected.
 • For main setpoint nMainSetValue_a, the set acceleration time (C00012
) and 
deceleration time (C00013
) are active in the case of the binary coded selection "0" 
(all inputs = FALSE or not assigned).
 • Alternative acceleration times are selected in C00101/1...15
.
 • The selection of the alternative deceleration times is carried out in C00103/1...15
.
 • For a detailed functional description see FB L_NSet
.
bJogRamp4
bJogRamp8
BOOL
Identifier
Data type
Information/possible settings
efesotomasyon.com - Lenze