Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010 L 297
8400 HighLine | Parameter setting & configuration
Technology applications
TA "Table positioning"
 
nAuxSetValue_a
INT
Additional speed setpoint
 • Offset and gain of this input signal can be adjusted in C00697
 and C00671 for a 
simple adjustment of a setpoint encoder.
 • Scaling: 16384 ≡ 100 % rated speed (C00011
)
 • The additional speed setpoint can be linked arithmetically with the main speed 
setpoint behind the ramp function generator.
 • The additional speed setpoint can be shown via ramp times of a second ramp 
function generator.
 • For a detailed functional description see FB L_NSet
.
bJogSpeed1
bJogSpeed2
BOOL
Selection inputs for fixed changeover setpoints (JOG setpoints) for the main setpoint
 • Selection inputs are binary coded.
bJogSpeed1
bJogSpeed2
BOOL
Selection inputs for fixed changeover setpoints (JOG setpoints) for the main setpoint
 • A fixed setpoint for the setpoint generator can be activated instead of the main 
setpoint via these selection inputs.
 • The two selection inputs are binary coded, therefore you can select 3 fixed 
setpoints.
 • In the case of binary coded selection "0" (all inputs = FALSE or not assigned), main 
setpoint nMainSetValue_a is active.
 • The selection of the fixed setpoints is executed in C00039/1...3
 in [%] based on 
the reference speed (C00011
).
 • For a detailed functional description see FB L_NSet
.
Motor potentiometer
Alternatively to the input signal nMainSetValue_a, the main setpoint can also be generated by a motor 
potentiometer function.
 • In the Lenze setting, the motor potentiometer function is deactivated.
 • Activation is possible via C00806
 or via the bMPotEnable input.
 • The behaviour of the motor potentiometer during switch-on of the drive system can be selected in C00805
.
 • For a detailed functional description see FB L_MPot
.
bMPotEnable
BOOL
Activating the motor potentiometer function
 •This input and C00806
 are OR'd.
TRUE The motor potentiometer function is active; the speed setpoint can 
be changed via the bMPotUp and bMPotDown control inputs.
bMPotUp
BOOL
Increasing the speed setpoint
TRUE Approach the upper speed limit value set in C00800 with the 
acceleration time set in C00802
.
bMPotDown
BOOL
Decreasing the speed setpoint
TRUE Approach the lower speed limit value set In C00801
 with the 
deceleration time set in C00803
.
MCK basic functions
bMBrakeRelease
BOOL
Holding brake control: Release/apply brake
 • In conjunction with the operating mode selected in C02580
 
(Lenze setting: "Brake control off").
FALSE Apply brake.
 • During automatic operation, the internal brake logic controls of 
the brake.
TRUE Release brake.
 • During automatic operation, the internal brake logic is 
deactivated and the brake is released. If the brake control has 
inhibited the controller, this inhibit is deactivated again.
wMckCtrl1
wMckCtrl2
WORD
Direct selection of MCK control words
 • E.g. via a master control which has been connected to the fieldbus, too. For this 
purpose, the control word inputs can directly be connected to the LP_MciIn or 
LP_CanIn fieldbus interface.
 • See the "MCK control word
" chapter for a detailed description of the individual 
control bits.
Identifier
Data type
Information/possible settings