8400 HighLine | Parameter setting & configuration
Technology applications
TA "Switch-off positioning"
330 L Firmware 05.00 - DMS 4.2 EN - 02/2010
nTorqueMotLim_a
nTorqueGenLim_a
INT
Torque limitation in motor mode and in generator mode
These input signals are directly transferred to the motor control to limit the
controller's maximum torque in motor and generator mode.
The drive cannot output a higher torque in motor/generator mode than set here.
The applied values (any polarity) are internally interpreted as absolute values.
If V/f characteristic control (VFCplus) is selected, limitation is indirectly
performed via a so-called I
max
controller.
If sensorless vector control (SLVC) or servo control (SC) is selected, limitation has
a direct
effect on the torque-producing current component.
Scaling: 16384 100 % M
max
(C00057)
Torque limits in motor and generator mode:
bSetSpeedCcw
BOOL
Change of direction of rotation
For instance if a motor or gearbox is fixed laterally reversed to a machine part, but
the setpoint selection should still be executed for the positive direction of
rotation.
FALSE Direction of rotation to the right (Cw)
TRUE Direction of rotation to the left (Ccw)
bRLQCw
BOOL
Activate clockwise rotation (fail-safe)
For a detailed functional description see FB L_RLQ
.
FALSE Quick stop
TRUE Clockwise rotation
bRLQCcw
BOOL
Activate counter-clockwise rotation (fail-safe)
For a detailed functional description see FB L_RLQ
.
FALSE Quick stop
TRUE Counter-clockwise rotation
nMainSetValue_a
INT
Main speed setpoint
Offset and gain of this input signal can be set in C00696
and C00670 for a simple
signal adjustment of a setpoint encoder.
Scaling: 16384 100 % rated speed (C00011
)
The main setpoint is transformed to a speed setpoint in the setpoint encoder via
a ramp function generator with linear or S-shaped ramps.
Upstream to the ramp function generator, a blocking speed masking function
and a setpoint MinMax limitation are effective.
For a detailed functional description see FB L_NSet
.
nAuxSetValue_a
INT
Additional speed setpoint
Offset and gain of this input signal can be adjusted in C00697
and C00671 for a
simple adjustment of a setpoint encoder.
Scaling: 16384 100 % rated speed (C00011
)
The additional speed setpoint can be linked arithmetically with the main speed
setpoint behind the ramp function generator.
The additional speed setpoint can be shown via ramp times of a second ramp
function generator.
For a detailed functional description see FB L_NSet
.
Identifier
Data type
Information/possible settings
n
N
M
N
M
-M
N
-n
N
n
TorqueMotLim
TorqueGenLim
TorqueMotLim
TorqueMotLim
TorqueGenLim