Port block LP_MciOut
bState_B0 LA_SwitchPos.bDriveFail 1 Drive controller in error status
•"Fault
" device state is active.
bState_B1 - -
bState_B2 LA_SwitchPos.bDriveReady 1 Drive controller is ready for operation
•"SwitchedON
" device state is active.
The drive is in this device state if the DC bus voltage is
applied and the controller is still inhibited by the user
(controller inhibit).
bState_B3 LA_SwitchPos.bSpeedCcw 0 Direction of rotation to the right (Cw)
1 Direction of rotation to the left (Ccw)
bState_B4 LA_SwitchPos.bQspIsActive 1 Quick stop is active
bState_B5 LA_SwitchPos.bBrakeReleased 1 Brake released (after the brake opening time has elapsed)
bState_B6 - -
bState_B7 - -
bState_B8 - -
bState_B9 - -
bState_B1 - -
bState_B11 - -
bState_B12 - -
bState_B13 - -
bState_B14 LP_CanIn1.bCtrl1_B5 Binary coded selection of the switch-off position 1 ... 3
bState_B15 LP_CanIn1.bCtrl1_B6
wState LA_SwitchPos.wDriveControlStatus Status word of the controller (based on DSP-402)
See the wDeviceStatusWord status word
for the bit
assignment of the drive interface.
bOut2_B0 - -
...
bOut2_B15
wOut2 LA_SwitchPos.nMotorSpeedAct_a Actual speed value
Scaling: 16384 100 % rated speed (C00011
)
wOut3 LA_SwitchPos.nGPSignalOut1_a Analog signal monitor: Output signal 1
The selection of the signal source to output is executed in
C00410/1
.
Gain and offset for the output signal can be
parameterised in C00413/1
and C00413/2.
For a detailed functional description see
FB L_SignalMonitor_a
.
wOut4 - -
...
wOut16
dnOut34_p - -